AirGreat Company establishes the correct maintenance concepts and paid enough attention to maintenance. Good operating habits and regular maintenance could extend equipment life, reduce energy consumption, lower maintenance costs, avoid unexpected downtime, and substantially reduce the negative effects to production.
Attentions to the Routine Use
1. The normal switch and the stable supply for power, water, gas and temperature, especially the stability of power, if necessary, the voltage regulator could be installed to reduce the damage to the controller and the electromagnetic valve caused by power trouble;
2. Always pay attention to air flow, temperature and pressure of the import of freezing dryer. The evaporation pressure of freezing dryer should be maintained between 0.4 to 0.5 MPa without exceeding the rating;
3. Check daily automatic valve of sewage filter and the automatic drainage of freezing dryer to avoid loss role of drainage and sewerage for plugging;
4. Check weekly whether heat sink of freezing dryer is clean to avoid adverse affection caused by bad cooling system;
5. Conduct routine operation and maintenance in strict accordance with the requirements of equipment operator regulations, unscheduled check the sensitivity of solenoid valve and pneumatic valve, pressure range of pressure regulating valve, the accuracy of gas analyzer, the pressing situation of adsorption tower, exhaust muffler situation, the cleanliness of flowmeters, and so on;
6. Check the heating components of purification equipment, electrical control system, the amount of hydrogenation, the gas flow of drying tower, the temperature and time of regeneration.
Accessories Replacement Timetable
Accessories |
Change Period |
Cartridge of pipeline filters |
6 months or pressure indicator refers to the red regional |
Cartridge of fine filters |
12 months or pressure indicator refers to the red regional |
Cartridge of ultra-fine filters |
18 months or pressure indicator refers to the red regional |
Activated carbon |
18 months |
Solenoid Valve |
5 years |
Sensor |
different sensors different life |
Pneumatic valve seal |
6 years or frequency of use amounted to 1.5 million |
Cartridge of dust filters |
18 months or after each additional molecular sieve |
Carbon molecular sieve |
10 years |
13X molecular sieve |
5 years or dew point decline |
Deoxidization of carbon |
Single tower 3 months |
Catalyst to remove hydrogen |
5 years |